Firelock residential zone control riser module assembly. Chapter 1 offers an introduction to control valves, including definitions for common control valve and instrumentation terminology. End switches in each zone valve control the central circulator and the burner. When it comes to engine management, your valves couldnt play a more vital role.
Sprinkler zone control valve free download as pdf file. In this temperature and humidity range, we feel most comfortable. The zone control valve cabinet consists of two zone control valves. Victaulic is a leading fire protection manufacturer of innovative fire products and fire fighting systems including sprinklers, fire extinguishing and fire suppression systems, pipe couplings and fittings, and. Keles line of zone valves represent all of the major brands in the hvac control valve industry which includes belimo, caleffi, honeywell, schneider, siemens, spartan as well as our own kele branded zone. Free valve assembly, just ask september 2016 modulating poptop zone valves vm series floating thermostat 24 vac. Conversion kit allows you to convert a modumate zone control valve to a comforttrol zone control valve. Zone control valve zone control valve is a combined unit of 4 parts. All objects within this same range are comfortable to touch. Taco zone valve controls taco zone valve controls zvcs simplify wiring complicated controls. Tank pressure holding it closed is overcome by manual lift of the flapper. An improved sealing structure provides the valve itself and allows the separation noted above. Control valve unit action 7 actuator benchset range 8.
Valve assembly for zone control valves of the type employed in hydronic temperature control systems. In case of fire, it senses the water flow within the piping and converts it to the electrical signal to give warning and supplies water to piping. Heavy bronze body with sweat or threaded connections for heat pump and geothermal applications, taco offers l37906, which has corrosion. It may also provide stability, guiding, balance, and alignment, and facilitate assembly of other parts of the valve trim. Chapter 8 details typical control valve installation and maintenance procedures. This source of power can be manual hand, gear, chainwheel, lever, etc. The first zone control valve is a 112 tyco model dv5 body with a specific trim configuration designed for the ifp application, and the. For example, a 3 story apartment building with a valve room at the first floor.
Computer based simulation, design and sizing programs have been developing fast during past years and these are well in used by advanced control valve manufacturers to provide and. A zone valve is a specific type of valve used to control the flow of water or steam in a hydronic heating or cooling system in the interest of improving efficiency and occupant comfort, such systems are. Valves shown in the test position and with optional pressure relief valve kit installed. The load, in this case, is the device that is switched on when needed. The first zone control valve is a 112 tyco model dv5 body with a specific trim. They are assembled on fire pipeline to separates the. More particularly, the major units of this valve assembly 10 can be. J series electric zone valves for assembly in the field description j series electric zone valves accurately control the flow of saturated steam, hot water, and chilled water through coils and heat exchangers of all types, in a wide range of hvac applications. The zone control valve cabinet receives an alarm signal from the fire protection. The control valve handbook has been a primary reference since its first printing in 1965.
J series electric zone valves for assembly in the field. Zone valve is a type of valve that is used to regulate how much water flows through a closed heating or cooling system. The valve incorporates a control unit which can readily be separated from the valve structure without emptying fluid from the system. Zone valves by taco taco manufactures a wide array of products for heating and cooling zone control with applicationspecific zone valves designed to meet the individual project needs. The valve incorporates a control unit which can readily be separated from the valve structure without. Depending on the situation, we have shown all valves in a single valve room.
The ssassp electronic valve actuator requires a 24 vac power supply and receives a 0 to 10 vdc signal or a floating control signal to control a valve. They are assembled on fire pipeline to separates the fire area into small distribution zone for indication and control. A wide variety of zone control valve options are available to you, such as high pressure, low pressure. It prevents downstream demand from sacrificing supply of an upstream zone. The calibration of the actuator spring range of a control valve. General specification for fire service installation in government. Zone control valve is used to control the sprinkler system for each floor and yo separate the floors when a maintenance is needed at any specific floor. Sprinkler zone control valve fire sprinkler system valve. You can also choose from manual zone control valve, as well as from brass, stainless steel, and plastic. F840435 whi stem assembly 114 zone login for pricestock. Gossett 109054 conversion kit replacement operator head assembly with. In this post, we discuss the brief list of control valves pre. Fire sprinkler system design and installation requirements. Victaulic installation instructions series 747m firelock zone control riser module assembly.
A check valve, clack valve, nonreturn valve, reflux valve, retention valve or oneway valve is a. Valemo v23a1s motorized zone valve, 2way, 34 sweat, normally closed, 24 vac with end switch. Victaulic firelock one control riser module series 747m 10. This source of power can be manual hand, gear, chain wheel, lever, etc. Motorized ball zone valves highflow, high closeoff 6440 24v 3wire control actuator. A manual override device, using a lever, to stroke a valve or to limit its travel. Zone check valves are mandatorily used in the sprinkler system. Control valve study material instrumentation tools. Check valve news newspapers books scholar jstor october 2017 learn how and when to remove this template message. In case of fire, it senses the water flow within the piping and converts it to the electrical signal to give warning and supplies water to piping and sprinkler. This actuator is designed to work with zone control. Twoway onoff low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Taco zvc406exp4 expandable zone valve control 6 zone.
Chapter 2 develops the vital topic of control valve performance. The taco zone valve controls should be used in coordination with 2, 3, or 4wire zone valves. A control valve is a power operated device capable of modulating flow at varying degrees. Zone control valves interfacing videos pump testing comission and pump performance by rules of accored alliance,nfpa20,nfpa21,nfpa72. In this way, the control unit and the valve seals can be replaced. D chapter 8 offers typical control valve installation and maintenance proce dures. Zone control valve for fire sprinkler system tpmc tpmcsteel. Honeywell mzv series is the first linear zone valve with a builtin balancing plug that permits prebalancing for each zone. The spring return, twoposition design with synchronous motor has. Semirigid reel hose nph series fire pump set fire rated doors antiriot vehicle armoured mobile clinic 2mp, 20x, ir, wdr 1. Each level or fire zone shall be provided with a zone control valve assembly consists of. Generally such a system will be divided into zones, covering different parts of your. It requires extra bulk piping, but we put all three.
645 1387 1265 871 1507 178 160 163 1528 1150 811 1601 865 621 1346 755 200 941 503 1230 946 47 522 1087 210 1518 298 561 887 1474 1469 546 395 63 1651 1235 761 919 15 450 843 432 436 1419 1241 441 793